Thermocouples, Temperature Probes

Results: 31,275
Stocking Options
Environmental Options
Media
Exclude
31,275Results

Showing
of 31,275
Mfr Part #
Quantity Available
Price
Series
Package
Product Status
Element Type
Temperature Range
Length - Lead Wire
Conductor Type
Terminal Type
TC-K-TYPE
SENSOR TEMP -50~700C CONNECTOR
Olimex LTD
3,001
In Stock
1 : £1.29000
Bulk
-
Bulk
Active
K - Type
-50°C ~ 700°C
37.400" (95cm)
Non-Grounded
Connector
DFR0198
WATERPROOF DIGITAL TEMPE
DFRobot
2,804
In Stock
1 : £5.11000
Bulk
-
Bulk
Active
IC
-55°C ~ 125°C
-
-
Exposed Lead Wires
381
SENSOR TEMP -55~125C LEAD WIRE
Adafruit Industries LLC
1,147
In Stock
1 : £7.37000
Bulk
-
Bulk
Active
-
-55°C ~ 125°C
35.83" (910mm)
-
Exposed Lead Wires
SEN-11050
TEMP SENSOR WTRPRF DS18B20 11050
SparkFun Electronics
1,848
In Stock
1 : £8.34000
Bulk
-
Bulk
Active
IC
-55°C ~ 125°C
-
-
Exposed Lead Wires
642
HIGH TEMP WATERPROOF DS18B20 DIG
Adafruit Industries LLC
244
In Stock
1 : £11.08000
Bulk
-
Bulk
Active
-
-55°C ~ 125°C
35.43" (900.00mm)
-
Exposed Lead Wires
331
In Stock
1 : £11.19000
Bulk
Bulk
Active
Pt100
-40°C ~ 250°C
9.45" (240mm)
2 Conductor System
Eyelet
240-080
THERMOCOUPLE WIRE K-TYPE 1M
Digilent, Inc.
1,552
In Stock
1 : £15.56000
Bulk
-
Bulk
Active
K - Type
-73°C ~ 482°C
3.281' (1m)
-
Exposed Lead Wires
SA3-K-120
THERMOCOUPLE WITH SELF-ADHESIVE
Omega
147
In Stock
1 : £35.57000
Bulk
Bulk
Active
K - Type
-40°C ~ 260°C
-
Non-Grounded
Connector
SA3-K-SRTC
THERMOCOUPLE WITH SELF-ADHESIVE
Omega
215
In Stock
1 : £43.46000
Bulk
Bulk
Active
K - Type
-17°C ~ 260°C
6.667' (2.03m)
Non-Grounded
Exposed Lead Wires
SA3-K-SRTC
THERMOCOUPLE WITH SELF-ADHESIVE
Omega
46
In Stock
1 : £46.06000
Bulk
Bulk
Active
K - Type
-40°C ~ 260°C
3.333' (1.02m)
Non-Grounded
Connector
SA3-K-SRTC
THERMOCOUPLE WITH SELF-ADHESIVE
Omega
690
In Stock
1 : £48.22000
Bulk
Bulk
Active
K - Type
-40°C ~ 260°C
120.000" (3048.00mm)
Non-Grounded
Connector
SA1-J-72
THERMOCOUPLE WITH SELF-ADHESIVE
Omega
35
In Stock
1 : £107.56000
Bulk
Bulk
Active
K - Type
175°C
0.512" (13.00mm)
2 Conductor System
Exposed Lead Wires
SA1XL-E-72-SRTC
THERMOCOUPLE WITH SELF-ADHESIVE
Omega
102
In Stock
1 : £181.57000
Bulk
Bulk
Active
K - Type
260°C
-
Non-Grounded
Connector
EWSA-PT1000
AIR TEMPERATURE SENSOR, -40 C TO
Omega
27
In Stock
1 : £280.55000
Bulk
Bulk
Active
-
-
-
-
-
TC-K-TYPE-0.4M
SENSOR TEMP -50~700C LEAD WIRE
Olimex LTD
285
In Stock
1 : £1.29000
Bulk
-
Bulk
Active
K - Type
-50°C ~ 700°C
15.75" (400.00mm)
Grounded
Connector
TC-K-TYPE-1.5M
SENSOR TEMP -50~700C LEAD WIRE
Olimex LTD
500
In Stock
1 : £1.72000
Bulk
-
Bulk
Active
K - Type
-50°C ~ 700°C
4.921' (1.5m)
Grounded
Connector
3,186
In Stock
1 : £6.17000
Box
-
Box
Active
Thermistor
-40 ~ 100°C
-
Non-Grounded
Connector
898
In Stock
1 : £7.31000
Bulk
-
Bulk
Active
-
-40 ~ 180°C
3.70" (94.00mm)
Non-Grounded
Connector
314010819
PT1000 TEMPERATURE SENSOR PROBE
Seeed
187
In Stock
1 : £7.34000
Box
-
Box
Active
Pt1000
-50°C ~ 300°C
-
3 Conductor System
Exposed Lead Wires
270
THERMOCOUPLE TYPE-K GLASS BRAID
Adafruit Industries LLC
116
In Stock
1 : £7.37000
Bulk
-
Bulk
Active
K - Type
0 ~ 500°C
-
-
Exposed Lead Wires
680
In Stock
1 : £9.78000
Bulk
-
Bulk
Active
Thermistor
-40°C ~ 100°C
-
Non-Grounded
Connector
455-00036(B)
213MM SS TEMP PROBE 1320MM
Ezurio
223
In Stock
1 : £13.93000
Bulk
Bulk
Active
Temperature Probe
-
52.000" (1320mm)
-
-
455-00112
100MM SS RTD TEMPERATURE PROBE,
Ezurio
151
In Stock
1 : £22.39000
Bulk
Bulk
Active
Pt100
-25°C ~ 50°C
-
Non-Grounded
Connector
5024-0762
THERMOSTAT PROBE CONNECTOR
Sensata Technologies
102
In Stock
1 : £25.48000
Bulk
Bulk
Active
-
-55°C ~ 300°C
-
-
Connector
455-00124
RTD TEMP SENSOR CABLE ASSY
Ezurio
101
In Stock
1 : £27.10000
Bulk
Bulk
Active
Pt100
-100°C ~ 100°C
4.331' (1.32m)
Non-Grounded
Connector
Showing
of 31,275

What is a thermocouple?


A thermocouple is a rugged, reliable temperature sensor that converts a temperature difference directly into a measurable millivolt signal using the Seebeck effect. Made from two dissimilar metal wires joined at a sensing junction, thermocouples cover a broad range, from cryogenic temperatures below –200 °C up to noble metal types exceeding 1700 °C. For example, a Type K (nickel-chromium/nickel-alumel) is common in industrial furnaces, extrusion machines, and HVAC systems thanks to its wide range and durability. A Type J (iron-constantan) suits lower temperature ovens or kilns, while Types R and S (platinum-rhodium alloys) are chosen for extreme heat applications like glass production or aerospace engines.

A temperature probe, on the other hand, refers to the packaged form of a temperature sensor. A probe can house a thermocouple, RTD, or even a thermistor, mounted in a protective sheath with insulation and lead wires for practical use. In other words, a thermocouple is a sensing element, while a thermocouple probe is a ready-to-install assembly designed for a specific environment (e.g., food-safe stainless probes for dairy processing or Inconel-sheathed probes for turbines).

Like all sensors, thermocouples can fail. Key failure symptoms include:

Open circuit: No output signal due to a broken wire or corroded junction. Typically shows as an abnormally high or out-of-range reading.
Short circuit: Wires contact each other incorrectly, leading to unstable or inaccurate readings.
Drift: Gradual inaccuracy over time caused by oxidation, contamination, or mechanical stress, often critical in high-temperature industrial processes.
Noise or unstable signals: Can result from poor insulation, electromagnetic interference, or improper grounding.
Sluggish response: A sheath that has degraded or a partially damaged junction can cause delays in capturing real temperature changes.

Compared to RTDs, which excel in precision and stability but are more fragile, thermocouples are preferred where durability, wide temperature range, fast response, and lower cost matter most.