ECT/EPT Current Fault Sensor
Analog Devices' MAXREFDES38# features a low-power, 16-bit, high-accuracy, three-channel analog input
To realize the vision of a truly smart electricity grid, utilities must find ways to increase the speed at which they locate, isolate, and fix faults. The electronic current transformer/electronic potential transformer (ECT/EPT), or current fault sensor, fulfills this vision. Analog Devices' ECT/EPT is a low-power sensor that may be placed at many points in the grid, thereby increasing the granularity grid health data and fault location. These sensors must be ultra-low power because they generally receive energy from batteries or nearby fiber optic lines. Although power is readily present in the lines being measured, converting power from the kilovolts in the distribution lines is not feasible. In addition to low-power operation, these sensors must also maintain accuracy and performance, as they provide valuable grid health information during both faults and normal operation.
The term ECT/EPT refers to a variety of technologies applied to grid measurement applications. MAXREFDES38# specifically provides the low-power, high-speed, high-accuracy analog front-end designed for the ECT/EPT or current fault sensor application.
The MAXREFDES38# features a low-power, 16-bit, high-accuracy, three-channel analog input. Input channels can be configured as ±3 VP-P single-ended or ±6 VP- P differential. The MAXREFDES38# design integrates:
- a three-channel analog switch (MAX14531E);
- a quad precision, low-power buffer (MAX44245);
- a 16-bit fully differential ADC (MAX11901);
- an ultra-high-precision, 3 V voltage reference (MAX6126);
- a low-noise precision op amp (MAX44241);
- a supervisory circuit (MAX16058);
- a dual-output step-down DC-DC converter (MAX1775);
- a switched-capacitor voltage converter (MAX1044); and
- -3 V, 1.8 V, 3.3 V, 3.38 V, 4.5 V power rails (MAX1735/0MAX8891/1MAX8881/2MAX8902B/3MAX16910).
- High accuracy
- Low power
- Accepts 3 VP-P single-ended signal or 6 VP-P differential signal
- Optimized layout and size
- Device drivers
- Example C source code
- Test data
- ECT/EPT
- Current fault sensors
- Ultra-low power
- Small size
ECT/EPT Current Fault Sensor
| Image | Manufacturer Part Number | Description | Utilized IC / Part | Available Quantity | Price | View Details | |
|---|---|---|---|---|---|---|---|
![]() | MAXREFDES38# | EVAL BRD FOR MAX11901 MAX14531E | MAX11901, MAX14531E, MAX44245 | 2 - Immediate 25 - Factory Stock | $90.46 | View Details |