Fuses

Results: 29
Stocking Options
Environmental Options
Media
Exclude
29Results
Applied FiltersRemove All

Showing
of 29
Mfr Part #
Quantity Available
Price
Series
Package
Product Status
Mounting Type
Fuse Type
Current Rating (Amps)
Voltage Rating - AC
Response Time
Package / Case
Breaking Capacity @ Rated Voltage
Melting I²t
Approval Agency
Operating Temperature
Color
Size / Dimension
IEC Fuse 193, 195 Series
FUSE GLASS 4A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.11711
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
4 A
250 V
Slow Blow
5mm x 20mm
40A
42.0
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 5A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.11711
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
5 A
250 V
Slow Blow
5mm x 20mm
50A
70.0
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 6.3A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.11711
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
6.3 A
250 V
Slow Blow
5mm x 20mm
63A
120.0
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 8A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.11711
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
8 A
250 V
Slow Blow
5mm x 20mm
63A
240.0
cULus
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 10A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.13513
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
10 A
250 V
Slow Blow
5mm x 20mm
63A
400.0
cULus
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 12.5A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.13513
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
12.5 A
250 V
Slow Blow
5mm x 20mm
63A
650.0
cULus
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 2A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.13836
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
2 A
250 V
Slow Blow
5mm x 20mm
35A
10.0
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 2.5A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.13836
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
2.5 A
250 V
Slow Blow
5mm x 20mm
35A
14.0
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 3.15A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.13836
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
3.15 A
250 V
Slow Blow
5mm x 20mm
35A
25.0
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 800MA 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.14189
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
800 mA
250 V
Slow Blow
5mm x 20mm
35A
10.0
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 1A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.14189
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
1 A
250 V
Slow Blow
5mm x 20mm
35A
11.0
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 1.25A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.14189
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
1.25 A
250 V
Slow Blow
5mm x 20mm
35A
20.0
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 1.6A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.14189
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
1.6 A
250 V
Slow Blow
5mm x 20mm
35A
36.0
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 400MA 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.14752
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
400 mA
250 V
Slow Blow
5mm x 20mm
35A
2.4
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 500MA 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.14752
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
500 mA
250 V
Slow Blow
5mm x 20mm
35A
3.8
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 630MA 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.14752
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
630 mA
250 V
Slow Blow
5mm x 20mm
35A
7.5
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 315MA 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.15991
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
315 mA
250 V
Slow Blow
5mm x 20mm
35A
1.1
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 16A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.16216
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
16 A
250 V
Slow Blow
5mm x 20mm
-
-
-
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 250MA 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.16779
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
250 mA
250 V
Slow Blow
5mm x 20mm
35A
0.32
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 200MA 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.18693
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
200 mA
250 V
Slow Blow
5mm x 20mm
35A
0.3
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
FUSE GLASS 8A 250VAC 5X20MM
FUSE GLASS 8A 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.22409
Bulk
Bulk
Obsolete
Through Hole
Cartridge, Glass
8 A
250 V
Slow Blow
5mm x 20mm (Axial)
63A
240.0
cULus
-
-
0.213" Dia x 0.827" L (5.40mm x 21.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 125MA 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.22747
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
125 mA
250 V
Slow Blow
5mm x 20mm
35A
0.13
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 160MA 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.22747
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
160 mA
250 V
Slow Blow
5mm x 20mm
35A
0.22
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 100MA 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.24774
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
100 mA
250 V
Slow Blow
5mm x 20mm
35A
0.073
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
IEC Fuse 193, 195 Series
FUSE GLASS 63MA 250VAC 5X20MM
Littelfuse Inc.
0
In Stock
1,000 : £0.27649
Bulk
Bulk
Obsolete
Requires Holder
Cartridge, Glass
63 mA
250 V
Slow Blow
5mm x 20mm
35A
0.026
BSI, CCEE, cULus, IMQ, SEMKO, VDE
-
-
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Showing
of 29

About Fuses


Fuses are fundamental circuit protection devices used in automotive and electronic systems to protect wiring and components from overcurrent, overload, and short circuit conditions. Under normal operation, current flows through a calibrated metal element designed for a specific rating. When current exceeds that limit, due to a short circuit, inrush current, or sustained overload, the element heats and melts, permanently opening the circuit. Because most fuses are non-resettable, they must be replaced after operation. They provide fast, reliable protection for both low-voltage and high-voltage circuits.

Common formats include mini, low-profile mini, ATO/ATC, and maxi fuses. Selection must match:

  • Current rating (never oversize)
  • Physical format (fit in fuse block)
  • Ambient temperature derating (high under-hood temps reduce effective capacity)
  • Load behavior (steady vs inrush-heavy circuits) using time-current selection curves
  • PCB / SMD Fuse Selection & Behavior

In electronic circuits, SMD fuses protect low-voltage PCB traces and components. Proper selection depends on:

Rated current and voltage
  • Fast-acting vs time-delay response
  • Ambient temperature derating (hot boards reduce fuse capacity)
  • Surge tolerance using manufacturer time-current curves

These factors ensure the fuse survives normal transients but opens under true fault conditions without damaging the board.

Troubleshooting & Replacement Checklist
  • Confirm failure
  • Check loss of circuit function
  • Verify with multimeter continuity test (do not rely on visual inspection alone)
  • Check for root cause
  • Look for parasitic draw conditions (unexpected current drain)
  • Inspect wiring for shorts or overload sources
  • Verify fuse holder contact integrity (loose, corroded, or heat-damaged terminals)
  • Replace correctly
  • Match exact amperage rating
  • Match physical size and type
  • Match response type (fast vs time-delay)
If a replacement fuse blows immediately, the fault is still present and must be resolved before re-energizing the circuit.